{"product_id":"hpo-tec-trojan-monoplace-hyperbaric-chamber","title":"HPO TEC TROJAN Monoplace Hyperbaric Chamber","description":"\u003c!-- TROJAN Monoplace Hyperbaric Chamber — mediriser.com Shopify Product Description --\u003e\u003c!-- CSS Prefix: trojan1 --\u003e\u003c!-- Source: hpotech.com\/hyperbaric-chambers\/trojan\/ --\u003e\u003c!-- Section order: 1-Description | 2-Specifications | 3-Oxygen Concentrator Specifications | 4-Air Compressor Specifications | 5-Air Cooler Specifications | 6-Features | 7-Certifications --\u003e\n\u003cstyle\u003e\n  .trojan1 { font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, sans-serif; color: #1a2a3a; max-width: 900px; margin: 0 auto; line-height: 1.6; }\n  .trojan1 * { box-sizing: border-box; }\n  .trojan1 h2, .trojan1 h3 { font-weight: 700 !important; color: #0f172a !important; margin: 1.75rem 0 1rem; }\n  .trojan1 p { margin: 0 0 1rem; }\n\n  \/* Description paragraph card (no heading inside) *\/\n  .trojan1-intro-card { background: #fff; border: 1px solid #e2e8f0; border-radius: 8px; padding: 1rem 1.1rem 1.1rem; margin-bottom: 14px; }\n  .trojan1-intro-card p { font-size: 13px; color: #334155; margin: 0; line-height: 1.6; }\n\n  \/* Feature card grid: 2 columns *\/\n  .trojan1-feat-grid { display: grid; grid-template-columns: repeat(2, 1fr); gap: 14px; margin: 1rem 0; }\n\n  \/* Text-only feature card: h4 + text, no image *\/\n  .trojan1-text-card { background: #fff; border: 1px solid #e2e8f0; border-radius: 8px; padding: 1rem 1.1rem 1.1rem; }\n  .trojan1-text-card h4 { color: #0f172a !important; font-weight: 700 !important; font-size: 15px; margin: 0 0 0.45rem; line-height: 1.3; }\n  .trojan1-text-card p { font-size: 13px; color: #334155; margin: 0; line-height: 1.55; }\n\n  \/* Certifications *\/\n  .trojan1-cert-grid { display: grid; grid-template-columns: repeat(2, 1fr); gap: 12px; margin: 1rem 0; }\n  .trojan1-cert-card { display: flex; align-items: flex-start; gap: 12px; background: #fff; border: 1px solid #e2e8f0; border-radius: 8px; padding: 0.9rem 1rem; }\n  .trojan1-cert-card img { width: 52px; height: 52px; object-fit: contain; flex-shrink: 0; border-radius: 4px; }\n  .trojan1-cert-name { font-weight: 700; color: #0f172a; font-size: 13px; margin-bottom: 4px; }\n  .trojan1-cert-desc { font-size: 12px; color: #334155; margin: 0; line-height: 1.5; }\n\n  \/* Divider *\/\n  .trojan1-divider { border: none; border-top: 1px solid #e2e8f0; margin: 1.75rem 0; }\n\n  \/* FAQ accordion *\/\n  .trojan1-faq-item { border: 1px solid #e2e8f0; border-radius: 6px; margin-bottom: 10px; overflow: hidden; }\n  .trojan1-faq-item summary { list-style: none; cursor: pointer; padding: 0.9rem 1rem; font-weight: 700; color: #0f172a; display: flex; align-items: center; justify-content: space-between; gap: 10px; background: #f8fafc; }\n  .trojan1-faq-item summary::-webkit-details-marker { display: none; }\n  .trojan1-faq-item summary::after { content: \"+\"; font-size: 18px; font-weight: 700; color: #2563a8; flex-shrink: 0; }\n  .trojan1-faq-item[open] summary::after { content: \"\\2212\"; }\n  .trojan1-faq-item .trojan1-faq-answer { padding: 0.9rem 1rem; color: #334155; font-size: 14px; }\n\n  \/* Responsive *\/\n  @media(max-width: 900px) {\n    .trojan1-feat-grid { grid-template-columns: 1fr; }\n    .trojan1-cert-grid { grid-template-columns: 1fr; }\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"trojan1\"\u003e\n\u003c!-- =========================================================\n       H2 TITLE\n  ========================================================= --\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/hzcALjE-0UA?si=WqJw8Z34Zo1jPw_C\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2\u003eTROJAN is the monoplace hyperbaric chamber certified for medical applications\u003c\/h2\u003e\n\u003c!-- =========================================================\n       1. DESCRIPTION\n  ========================================================= --\u003e\n\u003cdiv class=\"trojan1-intro-card\"\u003e\n\u003cp\u003eThe TROJAN monoplace hyperbaric chamber is built from medical-grade aluminum, engineered to be lightweight, comfortable, and focused on delivering efficient hyperbaric oxygen therapy sessions. Operating at 2.0-2.4 ATA pressure, TROJAN is certified for medical applications and designed to accelerate the healing process. Each breath of pure oxygen, delivered through the BIBS mask under precise pressure control, empowers the immune system and promotes rapid recovery. Built-in entertainment, adjustable LED lighting, and ergonomic comfort make every session as relaxing as it is effective.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-intro-card\"\u003e\n\u003cp\u003eInside the TROJAN chamber, an ergonomic mattress adapts to your unique body shape, offering personalized comfort and pressure relief throughout the session. The interior is wrapped in high-quality ecologic leather upholstery for a comfortable, inviting feel with a classy finish. The external and internal control panels give both the operator and the patient full command of the session at all times, with mirrored controls, voice intercom, and an emergency stop available on both sides. UV-C light disinfection keeps the chamber interior clean and safe between sessions, while advanced monitoring sensors track all essential parameters in real time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003chr class=\"trojan1-divider\"\u003e\n\u003c!-- =========================================================\n       2. Specifications\n  ========================================================= --\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100% !important; max-width: none !important; table-layout: fixed; border-collapse: collapse; font-size: 13px; margin: 1rem 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #eaf1f9;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; color: #1e3a5f; font-weight: bold; text-transform: uppercase; font-size: 11px; letter-spacing: 0.03em;\" colspan=\"2\"\u003eGeneral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eCapacity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e1 Person (1 seat)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eMaterial\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003eAero-space aluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eShape and Design\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003eCylindrical shape, 1 module, designed to fit any standard doorway and space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eMaximum Patient Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e225 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #eaf1f9;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; color: #1e3a5f; font-weight: bold; text-transform: uppercase; font-size: 11px; letter-spacing: 0.03em;\" colspan=\"2\"\u003eDimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eOverall Length\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e2346 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eOverall Width\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e830 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e1087 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eInternal Length\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e810 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eInternal Volume\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e1 m3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e180 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eMinimum Installation Floor Size\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e4500 mm x 2600 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #eaf1f9;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; color: #1e3a5f; font-weight: bold; text-transform: uppercase; font-size: 11px; letter-spacing: 0.03em;\" colspan=\"2\"\u003eOperating Conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eMax. Operating Pressure\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e2.0 ATA (1.0 BAR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eDesign Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e0 degrees C to 38 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eEmergency Depressurization Rate\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e2.0 ATA to 1.0 ATA in 90 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #eaf1f9;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; color: #1e3a5f; font-weight: bold; text-transform: uppercase; font-size: 11px; letter-spacing: 0.03em;\" colspan=\"2\"\u003eAir Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eAir Pressurization\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e3.45 bar to 7.2 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eAir Supply Flow\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e250 LPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eVentilation Rate\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e125 LPM to 400 LPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #eaf1f9;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; color: #1e3a5f; font-weight: bold; text-transform: uppercase; font-size: 11px; letter-spacing: 0.03em;\" colspan=\"2\"\u003eOxygen Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eBIBS Oxygen Supply\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e3.2 bar to 4.0 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr class=\"trojan1-divider\"\u003e\n\u003c!-- =========================================================\n       3. Oxygen Concentrator Specifications\n  ========================================================= --\u003e\n\u003ch3\u003eOxygen Concentrator Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100% !important; max-width: none !important; table-layout: fixed; border-collapse: collapse; font-size: 13px; margin: 1rem 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #eaf1f9;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; color: #1e3a5f; font-weight: bold; text-transform: uppercase; font-size: 11px; letter-spacing: 0.03em;\" colspan=\"2\"\u003ePerformance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e2500 W \/ 3.3 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eOxygen Flow Range\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e1 to 20 LPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eOxygen Output Pressure\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e5 BAR \/ 72 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eOxygen Purity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e+-93%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eNoise Level\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e\u0026lt;= 72 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e155 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #eaf1f9;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; color: #1e3a5f; font-weight: bold; text-transform: uppercase; font-size: 11px; letter-spacing: 0.03em;\" colspan=\"2\"\u003eDimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eLength\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e695 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e481 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e1070 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr class=\"trojan1-divider\"\u003e\n\u003c!-- =========================================================\n       4. Air Compressor Specifications\n  ========================================================= --\u003e\n\u003ch3\u003eAir Compressor Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100% !important; max-width: none !important; table-layout: fixed; border-collapse: collapse; font-size: 13px; margin: 1rem 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #eaf1f9;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; color: #1e3a5f; font-weight: bold; text-transform: uppercase; font-size: 11px; letter-spacing: 0.03em;\" colspan=\"2\"\u003ePerformance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e4 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003ePressure Range\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e1 to 8 bar (116 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eAirflow Capacity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e564 LPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eNoise Level\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e46 decibels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e67 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #eaf1f9;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; color: #1e3a5f; font-weight: bold; text-transform: uppercase; font-size: 11px; letter-spacing: 0.03em;\" colspan=\"2\"\u003eDimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e495 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eLength\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e1004 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e804 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr class=\"trojan1-divider\"\u003e\n\u003c!-- =========================================================\n       5. Air Cooler Specifications\n  ========================================================= --\u003e\n\u003ch3\u003eAir Cooler Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100% !important; max-width: none !important; table-layout: fixed; border-collapse: collapse; font-size: 13px; margin: 1rem 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #eaf1f9;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; color: #1e3a5f; font-weight: bold; text-transform: uppercase; font-size: 11px; letter-spacing: 0.03em;\" colspan=\"2\"\u003ePerformance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e1 kW (at -10 degrees C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eTemperature Stability\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e+-0.1 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eSet Temperature Range\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e-10 degrees C to 40 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eCooling Method\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003eAir-cooled refrigeration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #eaf1f9;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; color: #1e3a5f; font-weight: bold; text-transform: uppercase; font-size: 11px; letter-spacing: 0.03em;\" colspan=\"2\"\u003eDimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e377 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eLength\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e500 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e640 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr class=\"trojan1-divider\"\u003e\n\u003c!-- =========================================================\n       6. Features — all uniform h4 + text cards, 2-column grid, no images\n  ========================================================= --\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv class=\"trojan1-feat-grid\"\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eBIBS Mask\u003c\/h4\u003e\n\u003cp\u003eThe Built-In Breathing System (BIBS) is regulated by the tempo of your breath. The BIBS regulator circulates oxygen effectively through the polyurethane hose while removing carbon dioxide, ensuring a safe and controlled therapy environment with always-pure oxygen breathing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eContinuous Flow of Oxygen\u003c\/h4\u003e\n\u003cp\u003eUnlike demand regulators, BIBS systems provide a constant flow of oxygen regardless of breathing patterns. This is beneficial for patients who struggle with deep breaths or have conditions affecting their respiratory muscles.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eReduced Risk of CO2 Buildup\u003c\/h4\u003e\n\u003cp\u003eThe system constantly flushes the chamber with fresh oxygen, helping prevent the buildup of carbon dioxide, which can be harmful at high pressures.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eSimplified Operation\u003c\/h4\u003e\n\u003cp\u003eBIBS systems require minimal interaction from the user, making them easier to use for patients with limited mobility or cognitive abilities.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eControlled Oxygen Concentration\u003c\/h4\u003e\n\u003cp\u003eThe flow rate of oxygen can be precisely adjusted to deliver the desired concentration, even if the pressure inside the chamber fluctuates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eExternal Control Panel\u003c\/h4\u003e\n\u003cp\u003eNavigate pressure adjustments, monitor vital information, maintain clear communication with your patient, and control every aspect of the chamber with confidence. Be prepared for any situation with manual overrides and an emergency stop button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eExternal Control Tablet\u003c\/h4\u003e\n\u003cp\u003eManage everything with the intuitive touchscreen control, from setting the pressure and session parameters to locking the chamber door. Monitor the session with clear visuals and data on chamber pressure, time, and other vital information.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eManual Compression Knob\u003c\/h4\u003e\n\u003cp\u003eTake command with the manual pressure knob, adjusting compression independently of the automatic system for greater control over session parameters.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eManual Decompression Knob\u003c\/h4\u003e\n\u003cp\u003eTake command with the manual pressure knob, adjusting decompression independently of the automatic system for greater control over session parameters.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eExternal Intercom\u003c\/h4\u003e\n\u003cp\u003eProvides voice connection with the user inside. It's always open for crystal clear communication with volume control, keeping operator and patient in continuous contact.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eEmergency Stop Button\u003c\/h4\u003e\n\u003cp\u003eTerminates the session in the pressure room if needed and quickly drops chamber pressure to a safe level. Available on both external and internal control panels for immediate safety response.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003ePower On Switch\u003c\/h4\u003e\n\u003cp\u003eThe switch turns on the electrical equipment, activating the control panels for manual and\/or automatic HBOT sessions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eEmergency Decompression Valve\u003c\/h4\u003e\n\u003cp\u003eIn case of emergency, the pressure chamber is relieved by rotating the manual spherical valve from inside or outside the chamber, providing a physical backup to all software controls.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eUSB Port\u003c\/h4\u003e\n\u003cp\u003eThe USB 3.0 port allows software updates, uploading custom settings, or downloading the session archive for record-keeping and clinical review.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eInternal Control Panel\u003c\/h4\u003e\n\u003cp\u003eTake charge of your hyperbaric experience with the intuitive internal control panel. Adjust pressure, time, and settings, all while monitoring key information on the built-in displays. All commands are mirrored for outside and inside user control.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eInternal Control Tablet\u003c\/h4\u003e\n\u003cp\u003eManage everything from within the chamber with the intuitive touchscreen, from setting pressure and session parameters to monitoring all vital information during treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eChamber Pressure Indicator\u003c\/h4\u003e\n\u003cp\u003eA mechanical dial indicator provides a quick analog reading of pressure variations inside the chamber, giving the patient an instant visual reference at all times.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eInternal Cooler\u003c\/h4\u003e\n\u003cp\u003eOperated using the control tablet, the internal cooler adjusts chamber temperature when pressurized, maintaining a comfortable HBOT session experience throughout.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eInternal Intercom\u003c\/h4\u003e\n\u003cp\u003eProvides voice communication with outside operators. It's always open with a crystal clear connection, ensuring the patient is never isolated during treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eUV-C Light Disinfection\u003c\/h4\u003e\n\u003cp\u003eThe chamber features UV-C light disinfection that inactivates viruses and bacteria from surfaces and ambient air, keeping the interior environment clean and safe between sessions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eOccupancy Sensor\u003c\/h4\u003e\n\u003cp\u003eAutomatically disables UV-C when someone enters the pressure chamber, ensuring disinfection operates only when safe and the chamber is unoccupied.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eAutomation System\u003c\/h4\u003e\n\u003cp\u003eThe Automation System controls the chamber and runs sessions automatically. It consists of automation software, industrial PLC, sensors, valves, and PC. The PLC monitors and controls all connected devices, with specific functions dependent on customer configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eReal-Time Session Monitoring\u003c\/h4\u003e\n\u003cp\u003eReal-time session information is gathered from sensors and displayed to monitor session status. The monitoring systems track atmospheric pressure, oxygen concentration, temperature, humidity, patient vitals, and treatment duration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eSession Status Management\u003c\/h4\u003e\n\u003cp\u003eAutomatic session control for speed, pressure, and time. Entry of new treatment profiles. Chamber ventilation. I\/O calibration and other functions. Logging, reviewing, and printing tools. Session and patient information access. Real-time monitoring of temperature, humidity, pressure, and oxygen. Audio\/visual warnings to the operator. Valve openings or maximum compression\/decompression rate settings. Ear opening assistance. Session recording.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eErgonomic Mattress\u003c\/h4\u003e\n\u003cp\u003eThe ergonomic mattress adapts to your unique body shape, offering personalized comfort and pressure relief throughout the oxygen breathing session.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eInterior Leather\u003c\/h4\u003e\n\u003cp\u003eThe interior is wrapped in high-quality ecologic leather upholstery for the most comfortable and inviting feeling, together with a classy look.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003ePatient Monitoring\u003c\/h4\u003e\n\u003cp\u003eChamber penetrations and electrical connectors provide the capability to connect vital monitoring equipment such as EEG, ECG, TCOM, and blood pressure devices.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eEntertainment System\u003c\/h4\u003e\n\u003cp\u003eThe chamber is equipped with a large-screen TV or tablets for the user, including other customizable additions to improve the in-chamber experience.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eLED Lights\u003c\/h4\u003e\n\u003cp\u003eAdjustable LED RGB lighting allows you to create a serene and personalized atmosphere inside the chamber during each session.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eVentilation\u003c\/h4\u003e\n\u003cp\u003eThe automatic ventilation system ensures the air inside the chamber is always fresh throughout the duration of every session.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003ePneumatic Controls\u003c\/h4\u003e\n\u003cp\u003eChamber controls are completely pneumatic in nature and require only a compressed gas source, keeping operation clean and reliable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-text-card\"\u003e\n\u003ch4\u003eDiscrete Power Source\u003c\/h4\u003e\n\u003cp\u003eA discrete power source allows continued operation of chamber communications in the event of a power outage, maintaining safety and connectivity at all times.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr class=\"trojan1-divider\"\u003e\n\u003c!-- =========================================================\n       7. Certifications\n  ========================================================= --\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cp\u003eHPO TECH hyperbaric chambers comply with a wide range of international regulatory standards to ensure safety, quality, and operational excellence.\u003c\/p\u003e\n\u003cdiv class=\"trojan1-cert-grid\"\u003e\n\u003cdiv class=\"trojan1-cert-card\"\u003e\n\u003cimg alt=\"CE Mark\" src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/CE.jpg\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"trojan1-cert-name\"\u003e93\/42\/EEC - Medical Devices Directive (MDD)\u003c\/div\u003e\n\u003cp class=\"trojan1-cert-desc\"\u003eThis European Union directive ensures that HPO TECH hyperbaric chambers meet essential safety and performance requirements for medical devices. Compliance with MDD guarantees that the chambers are suitable for therapeutic use within healthcare settings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-cert-card\"\u003e\n\u003cimg alt=\"MDR 2017\/745\" src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/MDR-2017-745-Compliance-ezgif.com-webp-to-png-converter.png\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"trojan1-cert-name\"\u003eMedical Devices Directive (MDR)\u003c\/div\u003e\n\u003cp class=\"trojan1-cert-desc\"\u003eThe company has transitioned from the MDD certification to the new MDR framework, aligning with the latest EU medical device regulations for enhanced safety and performance standards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-cert-card\"\u003e\n\u003cimg alt=\"UKCA\" src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/ukca-logo-375x275-1.jpg\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"trojan1-cert-name\"\u003eUKCA - UK Conformity Assessed\u003c\/div\u003e\n\u003cp class=\"trojan1-cert-desc\"\u003eConfirms chambers meet post-Brexit UK regulatory requirements for medical devices, ensuring compliance with safety, performance, and environmental protection standards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-cert-card\"\u003e\n\u003cimg alt=\"ASME PVHO\" src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/hyperbaric-chamber-certifications-04.png\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"trojan1-cert-name\"\u003eASME PVHO - Pressure Vessels for Human Occupancy\u003c\/div\u003e\n\u003cp class=\"trojan1-cert-desc\"\u003eASME standard ensuring chambers are designed and built to safely accommodate human occupants under pressurized conditions, reducing risks associated with high-pressure environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-cert-card\"\u003e\n\u003cimg alt=\"ASME U-Stamp\" src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2026\/01\/asme-2.png\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"trojan1-cert-name\"\u003eASME U-Stamp\u003c\/div\u003e\n\u003cp class=\"trojan1-cert-desc\"\u003eASME certification confirming the pressure vessel complies with strict safety, design, fabrication, and testing standards under Section VIII, Division 1 of the BPVC.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-cert-card\"\u003e\n\u003cimg alt=\"PED\" src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/PED.jpg\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"trojan1-cert-name\"\u003ePED - Pressure Equipment Directive\u003c\/div\u003e\n\u003cp class=\"trojan1-cert-desc\"\u003eEuropean standard regulating the design, manufacturing, and testing of pressurized equipment, ensuring hyperbaric chambers can safely handle the pressures required for hyperbaric therapy.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-cert-card\"\u003e\n\u003cimg alt=\"ISO 13485\" src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/hyperbaric-chamber-certifications-02-1.png\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"trojan1-cert-name\"\u003eISO 13485 - Medical Devices Quality Management System\u003c\/div\u003e\n\u003cp class=\"trojan1-cert-desc\"\u003eConfirms adherence to internationally recognized standards for medical device manufacturing and quality control throughout the product lifecycle.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-cert-card\"\u003e\n\u003cimg alt=\"ISO 45001\" src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/hyperbaric-chamber-certifications-02-1.png\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"trojan1-cert-name\"\u003eISO 45001 - Occupational Health and Safety Management System\u003c\/div\u003e\n\u003cp class=\"trojan1-cert-desc\"\u003eEnsures chambers are manufactured under a management system that prioritizes employee safety and health in the workplace.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-cert-card\"\u003e\n\u003cimg alt=\"ISO 9001\" src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/hyperbaric-chamber-certifications-02-1.png\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"trojan1-cert-name\"\u003eISO 9001 - Quality Management System\u003c\/div\u003e\n\u003cp class=\"trojan1-cert-desc\"\u003eCovers mechanical safety of hyperbaric chambers including moving parts, emergency stops, and user interfaces to protect operators and patients.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-cert-card\"\u003e\n\u003cimg alt=\"ISO 14001\" src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/hyperbaric-chamber-certifications-02-1.png\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"trojan1-cert-name\"\u003eISO 14001 - Environmental Management System\u003c\/div\u003e\n\u003cp class=\"trojan1-cert-desc\"\u003eConfirms the company follows environmental best practices in its manufacturing processes, reducing ecological impact and ensuring sustainability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-cert-card\"\u003e\n\u003cimg alt=\"ISO 27001\" src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/hyperbaric-chamber-certifications-02-1.png\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"trojan1-cert-name\"\u003eISO 27001 - Information Security Management System\u003c\/div\u003e\n\u003cp class=\"trojan1-cert-desc\"\u003eEnsures protection of sensitive patient and operational data through strict information security management protocols.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-cert-card\"\u003e\n\u003cimg alt=\"2001\/95\/EC\" src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/10.jpg\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"trojan1-cert-name\"\u003e2001\/95\/EC - General Product Safety Directive\u003c\/div\u003e\n\u003cp class=\"trojan1-cert-desc\"\u003eEU directive setting general safety requirements for products placed on the EU market, complementing the CE marking under MDR.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-cert-card\"\u003e\n\u003cimg alt=\"Turk Lloydu\" src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/hyperbaric-chamber-certifications-05.png\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"trojan1-cert-name\"\u003eTurk Lloydu - Hydrostatic Testing and Conformity Assessment\u003c\/div\u003e\n\u003cp class=\"trojan1-cert-desc\"\u003eCertification for pressure testing and structural integrity of hyperbaric chambers, verifying safety and compliance with international hydrostatic standards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-cert-card\"\u003e\n\u003cimg alt=\"NFPA\" src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/hyperbaric-chamber-certifications-06.png\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"trojan1-cert-name\"\u003eNFPA - National Fire Protection Association (USA)\u003c\/div\u003e\n\u003cp class=\"trojan1-cert-desc\"\u003eEstablishes fire safety guidelines for hyperbaric chambers, ensuring compliance with strict fire prevention and suppression standards in medical environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-cert-card\"\u003e\n\u003cimg alt=\"ANEP 26\" src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/hyperbaric-chamber-certifications-13.png\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"trojan1-cert-name\"\u003eANEP 26 - Ergonomic Military Standards\u003c\/div\u003e\n\u003cp class=\"trojan1-cert-desc\"\u003eErgonomic standard establishing general human engineering design criteria for military systems, subsystems, equipment, and facilities.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-cert-card\"\u003e\n\u003cimg alt=\"Medsafe New Zealand\" src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/hyperbaric-chamber-certifications-08.png\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"trojan1-cert-name\"\u003eMedsafe, New Zealand\u003c\/div\u003e\n\u003cp class=\"trojan1-cert-desc\"\u003eNew Zealand's medical device regulatory body ensures HPO TECH chambers meet national healthcare standards for safety and effectiveness.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-cert-card\"\u003e\n\u003cimg alt=\"Thai FDA\" src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/03\/hyperbaric-chamber-certifications-32.png\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"trojan1-cert-name\"\u003eThai FDA - Thailand\u003c\/div\u003e\n\u003cp class=\"trojan1-cert-desc\"\u003eEnsures chambers meet strict safety and performance standards before legal sale in Thailand, signifying full regulatory compliance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-cert-card\"\u003e\n\u003cimg alt=\"FDA Ghana\" src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/11\/Certifications-19.png\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"trojan1-cert-name\"\u003eFDA - Ghana\u003c\/div\u003e\n\u003cp class=\"trojan1-cert-desc\"\u003eGhana FDA certification supporting healthcare, wellness, recovery, and human performance across Africa.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-cert-card\"\u003e\n\u003cimg alt=\"Saudi FDA SFDA\" src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/11\/Certifications-13.png\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"trojan1-cert-name\"\u003eSaudi Food and Drug Authority (SFDA)\u003c\/div\u003e\n\u003cp class=\"trojan1-cert-desc\"\u003eCertified as medical devices by the SFDA with full marketing authorization in the Kingdom of Saudi Arabia.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-cert-card\"\u003e\n\u003cimg alt=\"UAE Ministry of Health\" src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/11\/Certifications-21.png\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"trojan1-cert-name\"\u003eUAE - Ministry of Health\u003c\/div\u003e\n\u003cp class=\"trojan1-cert-desc\"\u003eCertified by both the UAE Ministry of Health and Prevention (MOHAP) and the Emirates Drug and Medical Devices Regulation Agency (EDE), affirming compliance with UAE medical and technical standards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-cert-card\"\u003e\n\u003cimg alt=\"UAE EDE\" src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2026\/06\/EDE-UAE.png\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"trojan1-cert-name\"\u003eUAE - Emirates Drug and Medical Devices Regulation Agency (EDE)\u003c\/div\u003e\n\u003cp class=\"trojan1-cert-desc\"\u003eDual certification with MOHAP confirming compliance with UAE regulatory requirements for medical device safety, quality, and clinical performance across hospitals and clinics throughout the Emirates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"trojan1-cert-card\"\u003e\n\u003cimg alt=\"Patents\" src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/11\/turk-patent-wipo-hague.png\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"trojan1-cert-name\"\u003ePatents\u003c\/div\u003e\n\u003cp class=\"trojan1-cert-desc\"\u003eAll chamber models are protected by design and utility model patents registered with Turk Patent and recognized internationally through the WIPO Hague System, covering Turkey, the EU, and the USA.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- END trojan1 --\u003e","brand":"Hpo Tec","offers":[{"title":"TROJAN - 2.0 ATA","offer_id":52456321974554,"sku":null,"price":59620.0,"currency_code":"USD","in_stock":true},{"title":"TROJAN - 2.4 ATA","offer_id":52456322007322,"sku":null,"price":68200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/1690\/0634\/files\/trojan-hyperbaric-chamber-8-768x1024.jpg?v=1783520202","url":"https:\/\/mediriser.com\/products\/hpo-tec-trojan-monoplace-hyperbaric-chamber","provider":"Mediriser","version":"1.0","type":"link"}