{"product_id":"hpo-tec-atlantis-multiplace-hyperbaric-chamber","title":"HPO TEC ATLANTIS Multiplace Hyperbaric Chamber","description":"\u003c!-- ATLANTIS 2-Seat Multiplace Hyperbaric Chamber — mediriser.com Shopify Product Description --\u003e\u003c!-- CSS Prefix: atlantis1 --\u003e\u003c!-- Source: hpotech.com\/hyperbaric-chambers\/atlantis\/ --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- Section order: 1-Description | 2-Specifications | 3-Oxygen Concentrator Specifications | 4-Air Compressor Specifications | 5-Air Cooler Specifications | 6-Features | 7-Certifications | 8-FAQ --\u003e\n\u003cstyle\u003e\n  .atlantis1 { font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, sans-serif; color: #1a2a3a; max-width: 900px; margin: 0 auto; line-height: 1.6; }\n  .atlantis1 * { box-sizing: border-box; }\n  .atlantis1 h2, .atlantis1 h3 { font-weight: 700 !important; color: #0f172a !important; margin: 1.75rem 0 1rem; }\n  .atlantis1 p { margin: 0 0 1rem; }\n\n  .atlantis1-intro-card { background: #fff; border: 1px solid #e2e8f0; border-radius: 8px; padding: 1rem 1.1rem 1.1rem; margin-bottom: 14px; }\n  .atlantis1-intro-card p { font-size: 13px; color: #334155; margin: 0; line-height: 1.6; }\n\n  .atlantis1-feat-grid { display: grid; grid-template-columns: repeat(2, 1fr); gap: 14px; margin: 1rem 0; }\n\n  .atlantis1-text-card { background: #fff; border: 1px solid #e2e8f0; border-radius: 8px; padding: 1rem 1.1rem 1.1rem; }\n  .atlantis1-text-card h4 { color: #0f172a !important; font-weight: 700 !important; font-size: 15px; margin: 0 0 0.45rem; line-height: 1.3; }\n  .atlantis1-text-card p { font-size: 13px; color: #334155; margin: 0; line-height: 1.55; }\n\n  .atlantis1-cert-grid { display: grid; grid-template-columns: repeat(2, 1fr); gap: 12px; margin: 1rem 0; }\n  .atlantis1-cert-card { display: flex; align-items: flex-start; gap: 12px; background: #fff; border: 1px solid #e2e8f0; border-radius: 8px; padding: 0.9rem 1rem; }\n  .atlantis1-cert-card img { width: 52px; height: 52px; object-fit: contain; flex-shrink: 0; border-radius: 4px; }\n  .atlantis1-cert-name { font-weight: 700; color: #0f172a; font-size: 13px; margin-bottom: 4px; }\n  .atlantis1-cert-desc { font-size: 12px; color: #334155; margin: 0; line-height: 1.5; }\n\n  .atlantis1-divider { border: none; border-top: 1px solid #e2e8f0; margin: 1.75rem 0; }\n\n  .atlantis1-faq-item { border: 1px solid #e2e8f0; border-radius: 6px; margin-bottom: 10px; overflow: hidden; }\n  .atlantis1-faq-item summary { list-style: none; cursor: pointer; padding: 0.9rem 1rem; font-weight: 700; color: #0f172a; display: flex; align-items: center; justify-content: space-between; gap: 10px; background: #f8fafc; }\n  .atlantis1-faq-item summary::-webkit-details-marker { display: none; }\n  .atlantis1-faq-item summary::after { content: \"+\"; font-size: 18px; font-weight: 700; color: #2563a8; flex-shrink: 0; }\n  .atlantis1-faq-item[open] summary::after { content: \"\\2212\"; }\n  .atlantis1-faq-item .atlantis1-faq-answer { padding: 0.9rem 1rem; color: #334155; font-size: 14px; }\n\n  @media(max-width: 900px) {\n    .atlantis1-feat-grid { grid-template-columns: 1fr; }\n    .atlantis1-cert-grid { grid-template-columns: 1fr; }\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"atlantis1\"\u003e\n\u003c!-- =========================================================\n       VIDEOS\n  ========================================================= --\u003e \u003c!-- Row 1: Video 1 + Video 2 side by side --\u003e\n\u003cdiv style=\"display: flex; gap: 12px; justify-content: center; flex-wrap: wrap; margin-bottom: 12px;\"\u003e\n\u003ciframe width=\"440\" height=\"248\" style=\"max-width: 100%; flex: 1 1 300px;\" src=\"https:\/\/www.youtube.com\/embed\/L_o0nFecmuM?si=RpK8-n-mqXs7WC9Y\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e \u003ciframe width=\"440\" height=\"248\" style=\"max-width: 100%; flex: 1 1 300px;\" src=\"https:\/\/www.youtube.com\/embed\/-ujtZX05gxo?si=tAuCByHtaHlh0dS4\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\n\u003c\/div\u003e\n\u003c!-- Row 2: Video 3 centered below --\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe width=\"560\" height=\"315\" style=\"max-width: 100%;\" src=\"https:\/\/www.youtube.com\/embed\/s9TVpdpps8E?si=QU_r2M2AZDuaQMr5\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c!-- =========================================================\n       H2 TITLE\n  ========================================================= --\u003e\n\u003ch2\u003eATLANTIS - Monoplace and Multiplace Hyperbaric Chamber for Two Users\u003c\/h2\u003e\n\u003c!-- =========================================================\n       1. DESCRIPTION\n  ========================================================= --\u003e\n\u003cdiv class=\"atlantis1-intro-card\"\u003e\n\u003cp\u003eThe ATLANTIS hyperbaric chamber is designed for two users to enjoy HBOT together. Built from medical-grade aerospace aluminium, lightweight and modular with a cylindrical 2-module design, ATLANTIS is focused on transparency, relaxation, and entertainment - all dedicated to two users sharing the benefits of hyperbaric oxygen therapy. Both users breathe pure oxygen through the Built-In Breathing System (BIBS), regulated by the tempo of their breath, ensuring each person receives the optimal level of oxygen for the most effective results. ATLANTIS can also be delivered as a monoplace single-seat chamber when required, powered by an automation system compliant with IEC 62304 Class C - the highest software safety standard for medical devices.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-intro-card\"\u003e\n\u003cp\u003eInside ATLANTIS, high-quality ecologic leather upholstery wraps the interior in comfort and style, with a choice of leather color, stitch color, stitch design, and embroidery options for full personalization. Ergonomic seating, adjustable LED RGB lighting, an entertainment system, and an advanced air cooling system create a calm and premium therapy environment for both users. ATLANTIS is equipped with an advanced medical sensor suite including high-accuracy CO2 tracking sensors, independent dual oxygen analyzers, IP65-rated temperature and humidity modules, and standard multi-port medical penetrators for the safe, pressure-sealed introduction of external medical lines such as clinical aspirators or ventilators. The system is also certified under CISPR 11 Class A and IEC 60601-1-2 medical standards for electromagnetic compatibility, ensuring zero interference with other hospital equipment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003chr class=\"atlantis1-divider\"\u003e\n\u003c!-- =========================================================\n       2. Specifications\n  ========================================================= --\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100% !important; max-width: none !important; table-layout: fixed; border-collapse: collapse; font-size: 13px; margin: 1rem 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #eaf1f9;\"\u003e\n\u003ctd colspan=\"2\" style=\"padding: 10px 14px; border: 1px solid #e2e8f0; color: #1e3a5f; font-weight: bold; text-transform: uppercase; font-size: 11px; letter-spacing: 0.03em;\"\u003eGeneral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eCapacity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e1 Person (1 seat) \/ 2 Persons (2 seats)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eMaterial\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003eAero-space aluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eShape and Design\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003eCylindrical shape, 2 modules, designed to fit any standard doorway and space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eModule Length\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e770 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eWorking \/ Design Pressure\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e3.0 ATA \/ 3.2 ATA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eTest Pressure\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e4.15 ATA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eMaximum Patient Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e225 kg per patient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #eaf1f9;\"\u003e\n\u003ctd colspan=\"2\" style=\"padding: 10px 14px; border: 1px solid #e2e8f0; color: #1e3a5f; font-weight: bold; text-transform: uppercase; font-size: 11px; letter-spacing: 0.03em;\"\u003eDimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eOverall Length\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e2151 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eOverall Width\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e2000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e1859 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eInternal Length\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e2200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eInternal Diameter\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e830 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eTotal Volume\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e4 m3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e650 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eMinimum Installation Floor Size\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e4400 mm x 3000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #eaf1f9;\"\u003e\n\u003ctd colspan=\"2\" style=\"padding: 10px 14px; border: 1px solid #e2e8f0; color: #1e3a5f; font-weight: bold; text-transform: uppercase; font-size: 11px; letter-spacing: 0.03em;\"\u003eOperating Conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eMax. Operating Pressure\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e2.0 ATA (1.0 BAR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eDesign Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e0 degrees C to 38 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eEmergency Depressurization Rate\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e2.0 ATA to 1.0 ATA in 90 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #eaf1f9;\"\u003e\n\u003ctd colspan=\"2\" style=\"padding: 10px 14px; border: 1px solid #e2e8f0; color: #1e3a5f; font-weight: bold; text-transform: uppercase; font-size: 11px; letter-spacing: 0.03em;\"\u003eAir Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eAir Pressurization\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e3.45 bar to 7.2 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eAir Supply Flow\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e450 LPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eVentilation Rate\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e125 LPM to 400 LPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #eaf1f9;\"\u003e\n\u003ctd colspan=\"2\" style=\"padding: 10px 14px; border: 1px solid #e2e8f0; color: #1e3a5f; font-weight: bold; text-transform: uppercase; font-size: 11px; letter-spacing: 0.03em;\"\u003eOxygen Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eBIBS Oxygen Supply\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e3.2 bar to 4.0 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr class=\"atlantis1-divider\"\u003e\n\u003c!-- =========================================================\n       3. Oxygen Concentrator Specifications\n  ========================================================= --\u003e\n\u003ch3\u003eOxygen Concentrator Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100% !important; max-width: none !important; table-layout: fixed; border-collapse: collapse; font-size: 13px; margin: 1rem 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #eaf1f9;\"\u003e\n\u003ctd colspan=\"2\" style=\"padding: 10px 14px; border: 1px solid #e2e8f0; color: #1e3a5f; font-weight: bold; text-transform: uppercase; font-size: 11px; letter-spacing: 0.03em;\"\u003ePerformance - 2 Units (1 per seat)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e2500 W \/ 3.3 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eOxygen Flow Range\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e1 to 20 LPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eOxygen Output Pressure\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e5 BAR \/ 72 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eOxygen Purity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e+-93%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eNoise Level\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e\u0026lt;= 72 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e155 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #eaf1f9;\"\u003e\n\u003ctd colspan=\"2\" style=\"padding: 10px 14px; border: 1px solid #e2e8f0; color: #1e3a5f; font-weight: bold; text-transform: uppercase; font-size: 11px; letter-spacing: 0.03em;\"\u003eDimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eLength\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e695 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e481 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e1070 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr class=\"atlantis1-divider\"\u003e\n\u003c!-- =========================================================\n       4. Air Compressor Specifications\n  ========================================================= --\u003e\n\u003ch3\u003eAir Compressor Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100% !important; max-width: none !important; table-layout: fixed; border-collapse: collapse; font-size: 13px; margin: 1rem 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #eaf1f9;\"\u003e\n\u003ctd colspan=\"2\" style=\"padding: 10px 14px; border: 1px solid #e2e8f0; color: #1e3a5f; font-weight: bold; text-transform: uppercase; font-size: 11px; letter-spacing: 0.03em;\"\u003ePerformance - 1 Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e4 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003ePressure Range\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e1 to 8 bar (116 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eAirflow Capacity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e564 LPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eNoise Level\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e46 decibels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e67 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #eaf1f9;\"\u003e\n\u003ctd colspan=\"2\" style=\"padding: 10px 14px; border: 1px solid #e2e8f0; color: #1e3a5f; font-weight: bold; text-transform: uppercase; font-size: 11px; letter-spacing: 0.03em;\"\u003eDimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e495 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eLength\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e1004 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e804 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr class=\"atlantis1-divider\"\u003e\n\u003c!-- =========================================================\n       5. Air Cooler Specifications\n  ========================================================= --\u003e\n\u003ch3\u003eAir Cooler Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100% !important; max-width: none !important; table-layout: fixed; border-collapse: collapse; font-size: 13px; margin: 1rem 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #eaf1f9;\"\u003e\n\u003ctd colspan=\"2\" style=\"padding: 10px 14px; border: 1px solid #e2e8f0; color: #1e3a5f; font-weight: bold; text-transform: uppercase; font-size: 11px; letter-spacing: 0.03em;\"\u003ePerformance - 1 Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e1 kW (at -10 degrees C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eTemperature Stability\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e+-0.1 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eSet Temperature Range\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e-10 degrees C to 40 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eCooling Method\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003eAir-cooled refrigeration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #eaf1f9;\"\u003e\n\u003ctd colspan=\"2\" style=\"padding: 10px 14px; border: 1px solid #e2e8f0; color: #1e3a5f; font-weight: bold; text-transform: uppercase; font-size: 11px; letter-spacing: 0.03em;\"\u003eDimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e377 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eLength\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e500 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; color: #64748b; width: 50%; font-weight: bold;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; border: 1px solid #e2e8f0; vertical-align: top; font-weight: 500; color: #0f172a;\"\u003e640 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr class=\"atlantis1-divider\"\u003e\n\u003c!-- =========================================================\n       6. Features — all uniform h4 + text cards, 2-column grid\n  ========================================================= --\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv class=\"atlantis1-feat-grid\"\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eBIBS Mask\u003c\/h4\u003e\n\u003cp\u003eThe Built-In Breathing System (BIBS) is regulated by the tempo of your breath. The BIBS regulator circulates oxygen effectively through the polyurethane hose while removing carbon dioxide, ensuring a safe and controlled therapy environment with always-pure oxygen breathing for both users.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eContinuous Flow of Oxygen\u003c\/h4\u003e\n\u003cp\u003eUnlike demand regulators, BIBS systems provide a constant flow of oxygen regardless of breathing patterns. This is beneficial for patients who struggle with deep breaths or have conditions affecting their respiratory muscles.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eReduced Risk of CO2 Buildup\u003c\/h4\u003e\n\u003cp\u003eThe system constantly flushes the chamber with fresh oxygen, helping prevent the buildup of carbon dioxide, which can be harmful at high pressures.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eSimplified Operation\u003c\/h4\u003e\n\u003cp\u003eBIBS systems require minimal interaction from the user, making them easier to use for patients with limited mobility or cognitive abilities.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eControlled Oxygen Concentration\u003c\/h4\u003e\n\u003cp\u003eThe flow rate of oxygen can be precisely adjusted to deliver the desired concentration, even if the pressure inside the chamber fluctuates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eExternal Control Panel\u003c\/h4\u003e\n\u003cp\u003eNavigate pressure adjustments, monitor vital information, maintain clear communication with your patient, and control every aspect of the chamber with confidence. Features a 10.1 inch industrial TFT touchscreen display with 1024x600 resolution and LED backlighting, unified main control console, internal audio hub, and proprietary chassis-integrated gas control valves.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eExternal Control Tablet\u003c\/h4\u003e\n\u003cp\u003eManage everything with the intuitive touchscreen control, from setting the pressure and session parameters to locking the chamber door. Monitor the session with clear visuals and data on chamber pressure, time, and other vital information.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eManual De\/Compression Knob\u003c\/h4\u003e\n\u003cp\u003eTake command with the manual pressure knobs, adjusting compression and decompression independently of the automatic system for greater control over any phase of the session.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003ePower On Switch\u003c\/h4\u003e\n\u003cp\u003eThe switch turns on the electrical equipment, activating the control panels for manual and\/or automatic HBOT sessions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eEmergency Decompression Valve\u003c\/h4\u003e\n\u003cp\u003eIn case of emergency, the pressure chamber is relieved by rotating the manual spherical valve from inside or outside the chamber, providing a physical backup to all software controls.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eEmergency Stop Button\u003c\/h4\u003e\n\u003cp\u003eTerminates the session in the pressure room if needed and quickly drops chamber pressure to a safe level. Available on both external and internal control panels.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eExternal Intercom\u003c\/h4\u003e\n\u003cp\u003eProvides voice connection with the users inside the chamber. Always open for crystal clear communication with volume control, ensuring continuous contact throughout every session.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eUSB Port\u003c\/h4\u003e\n\u003cp\u003eThe USB 3.0 port allows software updates, uploading custom settings, or downloading the session archive for record-keeping and clinical review.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eInternal Control Panel\u003c\/h4\u003e\n\u003cp\u003eTake charge of the hyperbaric experience from within. Features a 10.1 inch industrial TFT touchscreen display with 1024x600 resolution and LED backlighting. Adjust pressure, time, and settings while monitoring key information. All commands are mirrored for outside and inside user control.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eInternal Control Tablet\u003c\/h4\u003e\n\u003cp\u003eManage everything from within the chamber with the intuitive touchscreen, from setting pressure and session parameters to monitoring all vital information during treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eChamber Pressure Indicator\u003c\/h4\u003e\n\u003cp\u003eA mechanical dial indicator provides a quick analog reading of pressure variations inside the chamber, giving the patient an instant visual reference at all times.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eInternal Cooler\u003c\/h4\u003e\n\u003cp\u003eOperated using the control tablet, the internal cooler adjusts chamber temperature when pressurized, maintaining a comfortable HBOT session experience throughout.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eInternal Intercom\u003c\/h4\u003e\n\u003cp\u003eProvides voice communication with outside operators. Always open for crystal clear communication, ensuring users inside are never isolated during treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eUV-C Light Disinfection\u003c\/h4\u003e\n\u003cp\u003eThe chamber features UV-C light disinfection that inactivates viruses and bacteria from surfaces and ambient air, keeping the interior environment clean and safe between sessions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eOccupancy Sensor\u003c\/h4\u003e\n\u003cp\u003eAutomatically disables UV-C when someone enters the pressure chamber, ensuring disinfection operates only when the chamber is unoccupied and safe to run.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eCentralized Software Control\u003c\/h4\u003e\n\u003cp\u003eThe control consoles, located on the outside and inside the chamber, provide the controls and instrumentation for chamber operation including the gas control systems and communications system. The user-friendly interface allows customization of specific HBOT protocols with accurate metrics and simple controls.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eReal-Time Session Monitoring\u003c\/h4\u003e\n\u003cp\u003eSensors track essential parameters during HBOT sessions, enabling real-time monitoring and adjustments. The system gathers and displays real-time session information including pressure, oxygen, temperature, humidity, patient vitals, and treatment duration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eSession Status Management\u003c\/h4\u003e\n\u003cp\u003eThe protocols of each HBOT session are recorded in the data logger for future reference. This enables healthcare providers to observe treatment response, adjust protocols if necessary, and assess the overall progress of the therapy.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eAdvanced Automation System\u003c\/h4\u003e\n\u003cp\u003eThe chamber is fully automated via an advanced Automation System powered by automation software, industrial PLC, sensors, valves, and a PC. The PLC is the central control unit, monitoring and controlling all connected devices to streamline operations and reduce manual intervention. The system is compliant with IEC 62304 Class C - the highest software safety standard for medical devices.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eAdvanced Medical Sensor Suite\u003c\/h4\u003e\n\u003cp\u003eHigh-accuracy carbon dioxide (0-5000 ppm) tracking sensors, independent dual oxygen analyzers, and IP65-rated temperature and humidity modules provide comprehensive real-time environmental monitoring throughout every session.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eMulti-Port Medical Penetrators\u003c\/h4\u003e\n\u003cp\u003eStandard-equipped, welded blind-flanged penetrator ports allow the safe, pressure-sealed introduction of external medical lines such as clinical aspirators or ventilators, supporting advanced clinical monitoring inside the chamber.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eElectromagnetic Compatibility (EMC)\u003c\/h4\u003e\n\u003cp\u003eCertified under CISPR 11 Class A and IEC 60601-1-2 medical standards, ensuring zero electromagnetic interference with other sensitive hospital equipment during HBOT sessions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eErgonomic Seating\u003c\/h4\u003e\n\u003cp\u003eTailored to your body's physiology, the ergonomic seats reduce pressure point stress and boost circulation, ensuring a relaxed and effective session for both users. Choose between 3 ergonomic chair models with automatic or manual controls, including the luxury electric Maybach chair range with full customization options.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eInterior Leather\u003c\/h4\u003e\n\u003cp\u003eThe interior is wrapped in high-quality ecologic leather upholstery for the most comfortable and inviting feeling, with a classy look. Choose your favorite leather color, stitch color, stitch design, or embroidery options for a fully personalized interior.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003ePatient Monitoring\u003c\/h4\u003e\n\u003cp\u003eChamber penetrations and electrical connectors provide the capability to connect vital monitoring equipment such as EEG, ECG, TCOM, and blood pressure devices for both users simultaneously.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eEntertainment System\u003c\/h4\u003e\n\u003cp\u003eThe chamber is equipped with large-screen TV or tablets for the users, including other customizable additions to improve the in-chamber experience throughout the session.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eAdjustable LED RGB Lighting\u003c\/h4\u003e\n\u003cp\u003eAdjustable LED RGB lighting allows users and operators to create a personalized, serene atmosphere inside the chamber during each session.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eVentilation\u003c\/h4\u003e\n\u003cp\u003eThe automatic ventilation system ensures the air inside the chamber is always fresh throughout the duration of every session.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003ePneumatic Controls\u003c\/h4\u003e\n\u003cp\u003eChamber controls are completely pneumatic in nature and require only a compressed gas source, keeping operation clean and reliable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-text-card\"\u003e\n\u003ch4\u003eDiscrete Power Source\u003c\/h4\u003e\n\u003cp\u003eA discrete power source allows continued operation of chamber communications in the event of a power outage, maintaining safety and connectivity at all times.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr class=\"atlantis1-divider\"\u003e\n\u003c!-- =========================================================\n       7. Certifications\n  ========================================================= --\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cdiv class=\"atlantis1-cert-grid\"\u003e\n\u003cdiv class=\"atlantis1-cert-card\"\u003e\n\u003cimg src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/CE.jpg\" alt=\"CE Mark\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"atlantis1-cert-name\"\u003e93\/42\/EEC - Medical Devices Directive (MDD)\u003c\/div\u003e\n\u003cp class=\"atlantis1-cert-desc\"\u003eThis European Union directive ensures that HPO TECH hyperbaric chambers meet essential safety and performance requirements for medical devices. Compliance with MDD guarantees that the chambers are suitable for therapeutic use within healthcare settings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-cert-card\"\u003e\n\u003cimg src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/MDR-2017-745-Compliance-ezgif.com-webp-to-png-converter.png\" alt=\"MDR 2017\/745\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"atlantis1-cert-name\"\u003eMedical Devices Directive (MDR)\u003c\/div\u003e\n\u003cp class=\"atlantis1-cert-desc\"\u003eThe company has transitioned from the MDD certification to the new MDR framework, aligning with the latest EU medical device regulations for enhanced safety and performance standards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-cert-card\"\u003e\n\u003cimg src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/ukca-logo-375x275-1.jpg\" alt=\"UKCA\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"atlantis1-cert-name\"\u003eUKCA - UK Conformity Assessed\u003c\/div\u003e\n\u003cp class=\"atlantis1-cert-desc\"\u003eConfirms chambers meet post-Brexit UK regulatory requirements for medical devices, ensuring compliance with safety, performance, and environmental protection standards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-cert-card\"\u003e\n\u003cimg src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/hyperbaric-chamber-certifications-04.png\" alt=\"ASME PVHO\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"atlantis1-cert-name\"\u003eASME PVHO - Pressure Vessels for Human Occupancy\u003c\/div\u003e\n\u003cp class=\"atlantis1-cert-desc\"\u003eASME standard ensuring chambers are designed and built to safely accommodate human occupants under pressurized conditions, reducing risks associated with high-pressure environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-cert-card\"\u003e\n\u003cimg src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2026\/01\/asme-2.png\" alt=\"ASME U-Stamp\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"atlantis1-cert-name\"\u003eASME U-Stamp\u003c\/div\u003e\n\u003cp class=\"atlantis1-cert-desc\"\u003eASME certification confirming the pressure vessel complies with strict safety, design, fabrication, and testing standards under Section VIII, Division 1 of the BPVC.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-cert-card\"\u003e\n\u003cimg src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/PED.jpg\" alt=\"PED\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"atlantis1-cert-name\"\u003ePED - Pressure Equipment Directive\u003c\/div\u003e\n\u003cp class=\"atlantis1-cert-desc\"\u003eEuropean standard regulating the design, manufacturing, and testing of pressurized equipment, ensuring hyperbaric chambers can safely handle the pressures required for hyperbaric therapy.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-cert-card\"\u003e\n\u003cimg src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/hyperbaric-chamber-certifications-02-1.png\" alt=\"ISO 13485\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"atlantis1-cert-name\"\u003eISO 13485 - Medical Devices Quality Management System\u003c\/div\u003e\n\u003cp class=\"atlantis1-cert-desc\"\u003eConfirms adherence to internationally recognized standards for medical device manufacturing and quality control throughout the product lifecycle.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-cert-card\"\u003e\n\u003cimg src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/hyperbaric-chamber-certifications-02-1.png\" alt=\"ISO 45001\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"atlantis1-cert-name\"\u003eISO 45001 - Occupational Health and Safety Management System\u003c\/div\u003e\n\u003cp class=\"atlantis1-cert-desc\"\u003eEnsures chambers are manufactured under a management system that prioritizes employee safety and health in the workplace.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-cert-card\"\u003e\n\u003cimg src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/hyperbaric-chamber-certifications-02-1.png\" alt=\"ISO 9001\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"atlantis1-cert-name\"\u003eISO 9001 - Quality Management System\u003c\/div\u003e\n\u003cp class=\"atlantis1-cert-desc\"\u003eCovers mechanical safety of hyperbaric chambers including moving parts, emergency stops, and user interfaces to protect operators and patients.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-cert-card\"\u003e\n\u003cimg src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/hyperbaric-chamber-certifications-02-1.png\" alt=\"ISO 14001\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"atlantis1-cert-name\"\u003eISO 14001 - Environmental Management System\u003c\/div\u003e\n\u003cp class=\"atlantis1-cert-desc\"\u003eConfirms the company follows environmental best practices in its manufacturing processes, reducing ecological impact and ensuring sustainability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-cert-card\"\u003e\n\u003cimg src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/hyperbaric-chamber-certifications-02-1.png\" alt=\"ISO 27001\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"atlantis1-cert-name\"\u003eISO 27001 - Information Security Management System\u003c\/div\u003e\n\u003cp class=\"atlantis1-cert-desc\"\u003eEnsures protection of sensitive patient and operational data through strict information security management protocols.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-cert-card\"\u003e\n\u003cimg src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/10.jpg\" alt=\"2001\/95\/EC\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"atlantis1-cert-name\"\u003e2001\/95\/EC - General Product Safety Directive\u003c\/div\u003e\n\u003cp class=\"atlantis1-cert-desc\"\u003eEU directive setting general safety requirements for products placed on the EU market, complementing the CE marking under MDR.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-cert-card\"\u003e\n\u003cimg src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/hyperbaric-chamber-certifications-05.png\" alt=\"Turk Lloydu\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"atlantis1-cert-name\"\u003eTurk Lloydu - Hydrostatic Testing and Conformity Assessment\u003c\/div\u003e\n\u003cp class=\"atlantis1-cert-desc\"\u003eCertification for pressure testing and structural integrity of hyperbaric chambers, verifying safety and compliance with international hydrostatic standards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-cert-card\"\u003e\n\u003cimg src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/hyperbaric-chamber-certifications-06.png\" alt=\"NFPA\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"atlantis1-cert-name\"\u003eNFPA - National Fire Protection Association (USA)\u003c\/div\u003e\n\u003cp class=\"atlantis1-cert-desc\"\u003eEstablishes fire safety guidelines for hyperbaric chambers, ensuring compliance with strict fire prevention and suppression standards in medical environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-cert-card\"\u003e\n\u003cimg src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/hyperbaric-chamber-certifications-13.png\" alt=\"ANEP 26\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"atlantis1-cert-name\"\u003eANEP 26 - Ergonomic Military Standards\u003c\/div\u003e\n\u003cp class=\"atlantis1-cert-desc\"\u003eErgonomic standard establishing general human engineering design criteria for military systems, subsystems, equipment, and facilities.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-cert-card\"\u003e\n\u003cimg src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/01\/hyperbaric-chamber-certifications-08.png\" alt=\"Medsafe New Zealand\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"atlantis1-cert-name\"\u003eMedsafe, New Zealand\u003c\/div\u003e\n\u003cp class=\"atlantis1-cert-desc\"\u003eNew Zealand's medical device regulatory body ensures HPO TECH chambers meet national healthcare standards for safety and effectiveness.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-cert-card\"\u003e\n\u003cimg src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/03\/hyperbaric-chamber-certifications-32.png\" alt=\"Thai FDA\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"atlantis1-cert-name\"\u003eThai FDA - Thailand\u003c\/div\u003e\n\u003cp class=\"atlantis1-cert-desc\"\u003eEnsures chambers meet strict safety and performance standards before legal sale in Thailand, signifying full regulatory compliance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-cert-card\"\u003e\n\u003cimg src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/11\/Certifications-19.png\" alt=\"FDA Ghana\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"atlantis1-cert-name\"\u003eFDA - Ghana\u003c\/div\u003e\n\u003cp class=\"atlantis1-cert-desc\"\u003eGhana FDA certification supporting healthcare, wellness, recovery, and human performance across Africa.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-cert-card\"\u003e\n\u003cimg src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/11\/Certifications-13.png\" alt=\"Saudi FDA SFDA\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"atlantis1-cert-name\"\u003eSaudi Food and Drug Authority (SFDA)\u003c\/div\u003e\n\u003cp class=\"atlantis1-cert-desc\"\u003eCertified as medical devices by the SFDA with full marketing authorization in the Kingdom of Saudi Arabia.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-cert-card\"\u003e\n\u003cimg src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/11\/Certifications-21.png\" alt=\"UAE Ministry of Health\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"atlantis1-cert-name\"\u003eUAE - Ministry of Health\u003c\/div\u003e\n\u003cp class=\"atlantis1-cert-desc\"\u003eCertified by both the UAE Ministry of Health and Prevention (MOHAP) and the Emirates Drug and Medical Devices Regulation Agency (EDE), affirming compliance with UAE medical and technical standards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-cert-card\"\u003e\n\u003cimg src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2026\/06\/EDE-UAE.png\" alt=\"UAE EDE\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"atlantis1-cert-name\"\u003eUAE - Emirates Drug and Medical Devices Regulation Agency (EDE)\u003c\/div\u003e\n\u003cp class=\"atlantis1-cert-desc\"\u003eDual certification with MOHAP confirming compliance with UAE regulatory requirements for medical device safety, quality, and clinical performance across hospitals and clinics throughout the Emirates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"atlantis1-cert-card\"\u003e\n\u003cimg src=\"https:\/\/www.hpotech.com\/wp-content\/uploads\/2025\/11\/turk-patent-wipo-hague.png\" alt=\"Patents\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"atlantis1-cert-name\"\u003ePatents\u003c\/div\u003e\n\u003cp class=\"atlantis1-cert-desc\"\u003eAll chamber models are protected by design and utility model patents registered with Turk Patent and recognized internationally through the WIPO Hague System, covering Turkey, the EU, and the USA.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr class=\"atlantis1-divider\"\u003e\n\u003c!-- =========================================================\n       8. FAQ (always last)\n  ========================================================= --\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cdetails class=\"atlantis1-faq-item\"\u003e\n\u003csummary\u003eWhat is the Atlantis hyperbaric chamber designed for?\u003c\/summary\u003e\n\u003cdiv class=\"atlantis1-faq-answer\"\u003eThe HPOTECH Atlantis is a compact 2-seat multiplace hard-shell hyperbaric chamber for sports teams, athletic facilities, and wellness centers running shared-session recovery. Two users share one session in its cabin, giving facilities a practical entry point as they scale from individual monoplace sessions to group-based recovery programs.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"atlantis1-faq-item\"\u003e\n\u003csummary\u003eWhat pressure range does the Atlantis operate at?\u003c\/summary\u003e\n\u003cdiv class=\"atlantis1-faq-answer\"\u003eThe HPOTECH Atlantis 2-seat multiplace chamber operates within a 2.0-2.4 ATA pressure range. Our multiplace hard-shell chambers hold this standard range, built for simultaneous 2-person sessions at pressures suited to shared-cabin group recovery.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"atlantis1-faq-item\"\u003e\n\u003csummary\u003eHow does the Atlantis differ from other HPOTECH multiplace chambers?\u003c\/summary\u003e\n\u003cdiv class=\"atlantis1-faq-answer\"\u003eOur Atlantis is the smallest-footprint multiplace chamber in our lineup. Its compact 2-seat configuration and 2.0-2.4 ATA operating range set it apart from larger models like Mediterranean and Titan, suiting facilities with limited space or lower simultaneous-user needs compared to those larger shared-cabin chambers.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"atlantis1-faq-item\"\u003e\n\u003csummary\u003eWhat makes the Atlantis the right first multiplace step for a small clinical team?\u003c\/summary\u003e\n\u003cdiv class=\"atlantis1-faq-answer\"\u003eThe HPOTECH Atlantis offers the lowest multiplace entry point in the HPOTECH lineup, suited to a sports facility or wellness center moving from individual monoplace sessions to shared-cabin group sessions. Its compact 2-seat configuration lets a small team add recovery capacity without the larger footprint of multiplace models like Mediterranean or Titan.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"atlantis1-faq-item\"\u003e\n\u003csummary\u003eWhat does commissioning look like specifically for the Atlantis 2-seat configuration?\u003c\/summary\u003e\n\u003cdiv class=\"atlantis1-faq-answer\"\u003eHPOTECH scales Atlantis commissioning to its 2-seat configuration: on-site chamber installation, pressure-cycle verification across the 2.0-2.4 ATA range, door-seal integrity checks, and operator training before first use. The process runs from installation through operator sign-off, so the facility team can run sessions safely from day one.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c!-- END atlantis1 --\u003e","brand":"Hpo Tec","offers":[{"title":"ATLANTIS - 2.0 ATA","offer_id":52458246013210,"sku":null,"price":111000.0,"currency_code":"USD","in_stock":true},{"title":"ATLANTIS - 2.4 ATA","offer_id":52458246045978,"sku":null,"price":124000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/1690\/0634\/files\/atlantis-hyperbaric-chamber-HBOT-14-768x1024.jpg?v=1783567872","url":"https:\/\/mediriser.com\/products\/hpo-tec-atlantis-multiplace-hyperbaric-chamber","provider":"Mediriser","version":"1.0","type":"link"}