{"product_id":"harvia-club-k15g-club-series-15kw-sauna-heater","title":"Harvia Club K15G Club Series 15kW Sauna Heater","description":"\u003c!-- Harvia Club K15G - 15kW Club Series Electric Sauna Heater - HRKGU15CU1UL --\u003e\u003c!-- SKU: HRKGU15CU1UL | Club Series | 600-989 cu ft | Floor-standing | Home and commercial --\u003e\u003c!-- 240V\/1PH (listed SKU) - also available 208V\/3PH --\u003e\u003c!-- 240V\/1PH: 70A breaker \/ 4 AWG | 208V\/3PH: 50A breaker \/ 8 AWG --\u003e\u003c!-- Xenio CX45 or Fenix FX45 control required - sold separately --\u003e\u003c!-- 132 lbs AC3000 stones (3 boxes) sold separately --\u003e\u003c!-- Multi-layer construction - cooler surface | Rocks direct contact with elements --\u003e\u003c!-- UL Listed | Made in Finland by Harvia | Pallet delivery --\u003e\u003c!-- 5 document sections: IOM | Data Sheet | Stone Requirement | Harvia Suitable Sauna Stone Update 6\/22 | Harvia Heater Elements --\u003e\n\u003cstyle\u003e\n  .sl { font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, sans-serif; color: #1a2a3a; max-width: 900px; margin: 0 auto; line-height: 1.6; }\n  .sl * { box-sizing: border-box; }\n  .sl h4 { font-weight: 700 !important; color: #0f172a !important; margin: 1.5rem 0 0.5rem; line-height: 1.3; }\n  .sl h5 { font-weight: 700 !important; color: #0f172a !important; margin: 0 0 0.5rem; line-height: 1.3; }\n  .sl-hook { font-weight: 500 !important; line-height: 1.75 !important; color: #0f172a !important; padding: 1.1rem 1.4rem; background: #e8f0fa; border-left: 3px solid #2563a8; border-radius: 0 6px 6px 0; margin: 1.5rem 0; }\n  .sl-badges { display: flex; flex-wrap: wrap; gap: 7px; margin-bottom: 1.75rem; }\n  .sl-badge { background: #e8f0fa; color: #2563a8; font-size: 12px; font-weight: 600; padding: 5px 11px; border-radius: 4px; border: 1px solid #bfd4ef; white-space: nowrap; }\n  .sl-desc p { font-weight: 500 !important; line-height: 1.75 !important; color: #0f172a !important; margin: 0 0 1rem; }\n  .sl-desc p:last-child { margin: 0; }\n  .sl-spec-table { width: 100%; border-collapse: collapse; font-size: 15px; }\n  .sl-spec-table tr:nth-child(odd) { background: #f8fafc; }\n  .sl-spec-table td { padding: 9px 12px; border: 1px solid #e2e8f0; vertical-align: top; }\n  .sl-spec-table td:first-child { color: #64748b; width: 52%; }\n  .sl-spec-table td:last-child { font-weight: 700 !important; color: #0f172a !important; }\n  .sl-spec-grid { display: grid; grid-template-columns: 1fr 1fr; gap: 1.5rem; align-items: start; }\n  .sl-spec-tables { min-width: 0; }\n  .sl-spec-image { min-width: 0; }\n  .sl-spec-block { margin-bottom: 1.5rem; }\n  .sl-spec-block h4 { font-size: 16px; font-weight: 700 !important; color: #0f172a !important; margin: 1.5rem 0 0.6rem; padding-bottom: 0.4rem; border-bottom: 2px solid #2563a8; display: inline-block; }\n  .sl-inc-grid { display: grid; grid-template-columns: 1fr 1fr; gap: 0 1.25rem; }\n  .sl-inc-item { font-weight: 500 !important; color: #0f172a !important; padding: 10px 0 10px 22px; position: relative; border-bottom: 1px solid #e2e8f0; line-height: 1.5 !important; }\n  .sl-inc-item::before { content: \"\"; position: absolute; left: 4px; top: 16px; width: 6px; height: 6px; border-radius: 50%; background: #2563a8; }\n  .sl-feat-grid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; }\n  .sl-feat { background: #fff; border: 1px solid #e2e8f0; border-radius: 6px; padding: 0.9rem 1rem; }\n  .sl-feat-title { font-weight: 700 !important; color: #0f172a !important; margin-bottom: 6px; display: flex; align-items: center; gap: 7px; line-height: 1.3; }\n  .sl-feat-title::before { content: \"\"; display: inline-block; width: 7px; height: 7px; border-radius: 50%; background: #2563a8; flex-shrink: 0; }\n  .sl-feat p { font-weight: 500 !important; color: #0f172a !important; line-height: 1.6 !important; margin: 0; font-size: 14px; }\n  .sl-brand1, .sl-brand2 { display: grid; grid-template-columns: 1fr 1fr; gap: 2rem; align-items: center; padding: 1.5rem 0; }\n  .sl-brand-img { width: 100%; height: auto; border-radius: 8px; display: block; }\n  .sl-brand-tag { display: inline-block; font-size: 12px; font-weight: 600; letter-spacing: 0.09em; text-transform: uppercase; color: #2563a8; background: #e8f0fa; border: 1px solid #bfd4ef; border-radius: 4px; padding: 4px 10px; margin-bottom: 0.75rem; }\n  .sl-brand1 h4, .sl-brand2 h4 { font-size: 22px !important; font-weight: 700 !important; color: #0f172a !important; margin: 0 0 0.75rem; line-height: 1.3 !important; }\n  .sl-brand1 p, .sl-brand2 p { font-weight: 500 !important; line-height: 1.75 !important; color: #0f172a !important; margin: 0 0 0.9rem; }\n  .sl-brand1 p:last-child, .sl-brand2 p:last-child { margin: 0; }\n  .sl-check { list-style: none; padding: 0; margin: 1rem 0 0; }\n  .sl-check li { font-weight: 500 !important; line-height: 1.6 !important; color: #0f172a !important; padding: 10px 0 10px 22px; position: relative; border-bottom: 1px solid #e2e8f0; }\n  .sl-check li:last-child { border-bottom: none; }\n  .sl-check li::before { content: \"\"; position: absolute; left: 4px; top: 16px; width: 7px; height: 7px; border-radius: 50%; background: #2563a8; }\n  .sl-check li strong { color: #0f172a !important; font-weight: 700; }\n  .sl-notice { background: #eff6ff; border: 1px solid #bfd4ef; border-radius: 6px; padding: 0.9rem 1.1rem; margin-bottom: 1.5rem; font-weight: 500 !important; color: #1e3a5f !important; line-height: 1.6 !important; font-size: 14px; }\n  .sl-notice-yellow { background: #fffbeb; border: 1px solid #fcd34d; border-radius: 6px; padding: 0.9rem 1.1rem; margin-bottom: 1.5rem; font-weight: 500 !important; color: #78350f !important; line-height: 1.6 !important; font-size: 14px; }\n  .sl-notice-green { background: #f0fdf4; border: 1px solid #86efac; border-radius: 6px; padding: 0.9rem 1.1rem; margin-bottom: 1.5rem; font-weight: 500 !important; color: #14532d !important; line-height: 1.6 !important; font-size: 14px; }\n  .sl-warranty { background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; padding: 1.25rem 1.5rem; }\n  .sl-warranty p { font-weight: 500 !important; color: #0f172a !important; line-height: 1.7 !important; margin: 0 0 0.75rem; }\n  .sl-warranty p:last-child { margin: 0; }\n  .sl-manual { background: #fff; border: 1px solid #e2e8f0; border-radius: 6px; padding: 1.25rem 1.5rem; margin-bottom: 1.5rem; }\n  .sl-manual-item { margin-bottom: 1.25rem; padding-bottom: 1.25rem; border-bottom: 1px solid #e2e8f0; }\n  .sl-manual-item:last-child { margin-bottom: 0; padding-bottom: 0; border-bottom: none; }\n  .sl-manual-item h6 { font-size: 14px; font-weight: 700 !important; color: #0f172a !important; margin: 0 0 0.5rem; }\n  .sl-doc-link { display: inline-flex; align-items: center; gap: 7px; font-size: 14px; font-weight: 500; color: #4a5568; background: #fff; border: 1px solid #d1d5db; border-radius: 5px; padding: 8px 14px; text-decoration: none; }\n  .sl-doc-link:hover { background: #e8f0fa; border-color: #bfd4ef; color: #2563a8; }\n  .sl-divider { border: none; border-top: 1px solid #e2e8f0; margin: 1.75rem 0; }\n  @media (max-width: 768px) {\n    .sl-feat-grid { grid-template-columns: 1fr 1fr; }\n    .sl-spec-grid { grid-template-columns: 1fr; gap: 1.5rem; }\n    .sl-brand1, .sl-brand2 { grid-template-columns: 1fr; gap: 1rem; padding: 1rem 0; }\n    .sl-brand2 { display: flex; flex-direction: column-reverse; }\n    .sl-brand1 h4, .sl-brand2 h4 { font-size: 18px !important; }\n  }\n  @media (max-width: 480px) {\n    .sl { padding: 0; }\n    .sl-feat-grid { grid-template-columns: 1fr; gap: 8px; }\n    .sl-feat { padding: 0.8rem 0.9rem; }\n    .sl-inc-grid { grid-template-columns: 1fr; }\n    .sl-spec-grid { gap: 1.25rem; }\n    .sl-spec-table, .sl-spec-table tbody, .sl-spec-table tr, .sl-spec-table td { display: block; width: 100%; }\n    .sl-spec-table { border: none; }\n    .sl-spec-table tr { border: 1px solid #e2e8f0; border-radius: 6px; margin-bottom: 6px; padding: 8px 12px; background: #fff !important; }\n    .sl-spec-table tr:nth-child(odd) { background: #f8fafc !important; }\n    .sl-spec-table td { border: none; padding: 1px 0; }\n    .sl-spec-table td:first-child { font-size: 10px; font-weight: 600; letter-spacing: 0.06em; text-transform: uppercase; color: #64748b; width: 100%; padding-bottom: 2px; }\n    .sl-spec-table td:last-child { font-size: 15px; font-weight: 700 !important; color: #0f172a !important; width: 100%; word-wrap: break-word; overflow-wrap: break-word; }\n    .sl-divider { margin: 1.25rem 0; }\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"sl\"\u003e\n\u003cdiv class=\"sl-desc\"\u003e\n\u003ch2\u003eHarvia Club K15G Club Series 15kW Sauna Heater\u003c\/h2\u003e\n\u003cp\u003eThe Harvia Club K15G is a 15kW floor-standing electric sauna heater for large rooms from 600 to 989 cubic feet - designed for group use in homes, health clubs, day spas, apartment buildings, hotels, holiday resorts, sports centres, and swimming halls. This listing is for the 240V\/1PH configuration (SKU: HRKGU15CU1UL). A Xenio CX45 or Fenix FX45 control unit and 132 lbs of AC3000 sauna stones (3 boxes) are required for operation and sold separately. The Club K15G is the high-output floor-standing tier in Harvia's electric heater lineup - substantially more powerful than the wall-mounted KIP and Spirit series - built for saunas that operate continuously with large groups of bathers from morning through night.\u003c\/p\u003e\n\u003ch4\u003eClub Series - built for continuous group use\u003c\/h4\u003e\n\u003cp\u003eThe Club Series is Harvia's heavy-duty commercial-grade floor heater range. Where the KIP and Spirit series are sized for residential sauna rooms under 300 cubic feet, and the Virta Pro handles 354-1130 cu ft in high-output installations, the Club K15G occupies the 600-989 cu ft range with a purpose-built floor-standing unit designed for continuous operation under load. Harvia explicitly positions it for apartment buildings, hotels, holiday resorts, sports centres, swimming halls, and large family saunas - any installation where the heater needs to perform reliably for groups of bathers over extended daily operating periods. The steel outer shell, stainless steel interior and exterior, and multi-layer construction reflect the durability requirements of commercial-grade continuous use that a residential wall heater does not face.\u003c\/p\u003e\n\u003ch4\u003eMulti-layer construction - cooler surface and direct stone-to-element contact\u003c\/h4\u003e\n\u003cp\u003eThe Club K15G uses two engineering approaches to heat quality and safety. The first is multi-layer construction: multiple thermal layers between the heating core and the outer shell reduce the outer surface temperature during operation - providing a cooler exterior surface for a floor-standing heater in a high-traffic sauna environment where bathers, towels, and equipment pass close to the unit. The second is direct stone-to-element contact: the 132 lbs of AC3000 stones are loaded directly against the heating elements rather than sitting above them in a separate basket. Direct contact filters the intense radiant heat from the elements through the stone mass before it reaches the sauna air, producing a more comfortable, even heat rather than the harsh radiant output of unfiltered electric elements. The result is intense heat that is pleasant to bathe in rather than aggressive.\u003c\/p\u003e\n\u003ch4\u003eXenio CX45 or Fenix FX45 control - required for operation\u003c\/h4\u003e\n\u003cp\u003eThe Club K15G does not include a control unit and cannot operate without one. A Xenio CX45 or Fenix FX45 control is required and sold separately. The CX45 is Harvia's high-output Xenio control compatible with heaters up to 18kW; the FX45 is the corresponding Fenix touchscreen control with MyHarvia 2 app connectivity. Both are sold at BathingBrands. The 240V\/1PH configuration (this listing, HRKGU15CU1UL) requires a 70A dedicated breaker with 4 AWG wire. A licensed electrician is required for all electrical connections. Do not connect to a GFI\/GFCI breaker.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sl-hook\"\u003e15kW floor-standing electric sauna heater for rooms from 600 to 989 cubic feet. Club Series - designed for homes, health clubs, day spas, hotels, sports centres, and continuous group use. Multi-layer construction - cooler exterior surface. Rocks in direct contact with heating elements - even, penetrating heat. Xenio CX45 or Fenix FX45 control required (sold separately). Required: 132 lbs AC3000 stones (3 boxes, sold separately). 240V\/1PH: 70A breaker \/ 4 AWG. Deluxe stainless steel interior and exterior. UL Listed. Made in Finland by Harvia.\u003c\/div\u003e\n\u003cdiv class=\"sl-badges\"\u003e\n\u003cspan class=\"sl-badge\"\u003e15 kW\u003c\/span\u003e \u003cspan class=\"sl-badge\"\u003e600 to 989 cu ft\u003c\/span\u003e \u003cspan class=\"sl-badge\"\u003eClub Series - commercial and residential\u003c\/span\u003e \u003cspan class=\"sl-badge\"\u003eFloor-standing\u003c\/span\u003e \u003cspan class=\"sl-badge\"\u003eMulti-layer construction - cooler exterior\u003c\/span\u003e \u003cspan class=\"sl-badge\"\u003eRocks direct contact with elements - even heat\u003c\/span\u003e \u003cspan class=\"sl-badge\"\u003eXenio CX45 or Fenix FX45 required (sold separately)\u003c\/span\u003e \u003cspan class=\"sl-badge\"\u003e132 lbs AC3000 stones required (3 boxes)\u003c\/span\u003e \u003cspan class=\"sl-badge\"\u003e240V\/1PH | 70A breaker | 4 AWG wire\u003c\/span\u003e \u003cspan class=\"sl-badge\"\u003eDeluxe stainless steel interior and exterior\u003c\/span\u003e \u003cspan class=\"sl-badge\"\u003eUL Listed\u003c\/span\u003e \u003cspan class=\"sl-badge\"\u003eMade in Finland by Harvia\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sl-notice-yellow\"\u003e⚠️ \u003cstrong\u003eXenio CX45 or Fenix FX45 control required - not included. AC3000 stones required - not included.\u003c\/strong\u003e The Club K15G cannot operate without a control unit. A Xenio CX45 or Fenix FX45 must be purchased separately. 132 lbs of AC3000 sauna stones (3 boxes) must also be purchased separately. Note: this heater uses \u003cstrong\u003eAC3000\u003c\/strong\u003e stones, not the AC3020 used by most other Harvia heaters - confirm the correct stone model before ordering. A licensed electrician is required. Do not connect to a GFI\/GFCI breaker.\u003c\/div\u003e\n\u003cdiv class=\"sl-notice\"\u003eℹ️ \u003cstrong\u003e240V\/1PH electrical requirements.\u003c\/strong\u003e The 240V\/1PH configuration (HRKGU15CU1UL) requires a dedicated 70 Amp breaker and 4 AWG wire. A 208V\/3PH configuration is also available for commercial three-phase electrical systems (50A breaker, 8 AWG wire) - contact us if the 3PH configuration is needed. A licensed electrician is required for all electrical connections.\u003c\/div\u003e\n\u003chr class=\"sl-divider\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"sl-spec-grid\"\u003e\n\u003cdiv class=\"sl-spec-tables\"\u003e\n\u003cdiv class=\"sl-spec-block\"\u003e\n\u003ch4\u003eElectrical - 240V\/1PH (HRKGU15CU1UL)\u003c\/h4\u003e\n\u003ctable class=\"sl-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower output\u003c\/td\u003e\n\u003ctd\u003e15 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage \/ Phase\u003c\/td\u003e\n\u003ctd\u003e240V \/ 1-phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaker required\u003c\/td\u003e\n\u003ctd\u003e70 Amp dedicated breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire size\u003c\/td\u003e\n\u003ctd\u003e4 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl included\u003c\/td\u003e\n\u003ctd\u003eNo - Xenio CX45 or Fenix FX45 required (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sl-spec-block\"\u003e\n\u003ch4\u003eElectrical - 208V\/3PH (alternate)\u003c\/h4\u003e\n\u003ctable class=\"sl-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage \/ Phase\u003c\/td\u003e\n\u003ctd\u003e208V \/ 3-phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaker required\u003c\/td\u003e\n\u003ctd\u003e50 Amp dedicated breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire size\u003c\/td\u003e\n\u003ctd\u003e8 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact us\u003c\/td\u003e\n\u003ctd\u003eFor 3PH configuration availability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sl-spec-block\"\u003e\n\u003ch4\u003eRoom sizing and stones\u003c\/h4\u003e\n\u003ctable class=\"sl-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoom volume\u003c\/td\u003e\n\u003ctd\u003e600 to 989 cu ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStones required\u003c\/td\u003e\n\u003ctd\u003e132 lbs (3 boxes AC3000) - sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStone specification\u003c\/td\u003e\n\u003ctd\u003eAC3000 - see Stone Requirement document below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNote\u003c\/td\u003e\n\u003ctd\u003eAC3000 - not AC3020 - confirm before ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sl-spec-image\"\u003e\n\u003cdiv class=\"sl-spec-block\"\u003e\n\u003ch4\u003eConstruction and design\u003c\/h4\u003e\n\u003ctable class=\"sl-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFloor-standing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExterior\u003c\/td\u003e\n\u003ctd\u003eDeluxe stainless steel exterior\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterior\u003c\/td\u003e\n\u003ctd\u003eDeluxe stainless steel interior\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter shell construction\u003c\/td\u003e\n\u003ctd\u003eMulti-layer - cooler surface temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStone-to-element\u003c\/td\u003e\n\u003ctd\u003eDirect contact - filters harsh heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax sauna temperature\u003c\/td\u003e\n\u003ctd\u003e194°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in Finland by Harvia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sl-spec-block\"\u003e\n\u003ch4\u003eCompatible controls (sold separately)\u003c\/h4\u003e\n\u003ctable class=\"sl-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eXenio CX45\u003c\/td\u003e\n\u003ctd\u003eDigital wall control - up to 18kW heaters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFenix FX45\u003c\/td\u003e\n\u003ctd\u003e4.3\" touchscreen - MyHarvia 2 app - smart timer - 3 presets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoth\u003c\/td\u003e\n\u003ctd\u003eSold separately at BathingBrands\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNote\u003c\/td\u003e\n\u003ctd\u003eCX30 and FX30 are NOT compatible - CX45\/FX45 required for 15kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sl-spec-block\"\u003e\n\u003ch4\u003eClub Series in context\u003c\/h4\u003e\n\u003ctable class=\"sl-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eKIP \/ Spirit \/ Virta series\u003c\/td\u003e\n\u003ctd\u003eWall-mounted | Under 300 cu ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVirta Pro HL160E (16kW)\u003c\/td\u003e\n\u003ctd\u003eFloor-standing | 354-1130 cu ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClub K15G (this listing)\u003c\/td\u003e\n\u003ctd\u003eFloor-standing | 600-989 cu ft | Commercial + residential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKey Club distinction\u003c\/td\u003e\n\u003ctd\u003eBuilt for continuous group use - multi-layer - direct stone contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr class=\"sl-divider\"\u003e\n\u003ch3\u003eWhat's included\u003c\/h3\u003e\n\u003cdiv class=\"sl-inc-grid\"\u003e\n\u003cdiv class=\"sl-inc-item\"\u003eHarvia Club K15G 15kW floor-standing sauna heater - stainless steel\u003c\/div\u003e\n\u003cdiv class=\"sl-inc-item\"\u003eInstallation and operation manual\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin-top: 1rem; font-weight: 500; color: #64748b; font-size: 14px;\"\u003e\u003cstrong\u003eRequired (not included):\u003c\/strong\u003e Xenio CX45 or Fenix FX45 control unit (sold separately at BathingBrands); 132 lbs AC3000 stones - 3 boxes (sold separately - additional box recommended - note AC3000 not AC3020). \u003cstrong\u003eOptional (sold separately):\u003c\/strong\u003e 24-hour time clock accessory. A licensed electrician is required. Do not connect to a GFI\/GFCI breaker. 70A dedicated breaker and 4 AWG wire required for 240V\/1PH.\u003c\/p\u003e\n\u003chr class=\"sl-divider\"\u003e\n\u003ch3\u003eWhy the Harvia Club K15G stands out\u003c\/h3\u003e\n\u003cdiv class=\"sl-feat-grid\"\u003e\n\u003cdiv class=\"sl-feat\"\u003e\n\u003cdiv class=\"sl-feat-title\"\u003eHeavy-duty continuous group use\u003c\/div\u003e\n\u003cp\u003eThe Club K15G is the Harvia electric heater specifically built for high-demand continuous operation - the morning-to-night use pattern of apartment buildings, hotels, sports centres, and health clubs where the heater must perform reliably over extended daily sessions with multiple groups of users. The stainless steel construction, multi-layer outer shell, and direct stone-to-element design are all engineered for the more demanding thermal cycling and use intensity that commercial-grade continuous operation requires compared to residential intermittent use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sl-feat\"\u003e\n\u003cdiv class=\"sl-feat-title\"\u003eMulti-layer construction - cooler exterior\u003c\/div\u003e\n\u003cp\u003eThe multi-layer outer shell keeps the exterior surface cooler during operation than single-layer alternatives. In a high-traffic sauna where bathers, towels, and equipment regularly pass near the floor-standing heater, a cooler exterior surface reduces the risk of accidental contact burns. This is a particularly important safety characteristic for the commercial environments the Club K15G is designed for, where the user population is broad and the heater is used continuously rather than occasionally.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sl-feat\"\u003e\n\u003cdiv class=\"sl-feat-title\"\u003eDirect stone-to-element contact - filtered even heat\u003c\/div\u003e\n\u003cp\u003eThe 132-lb AC3000 stone mass is loaded directly against the heating elements. The stones absorb the initial intense radiant output of the elements and re-radiate it as a softer, more evenly distributed heat into the sauna air. This stone-filtered heat is more comfortable for large groups of bathers at high output levels than unfiltered element radiation. The large stone mass also provides a substantial thermal reservoir for water pouring (loyly) - at 132 lbs, the Club K15G produces generous, sustained steam when water is ladled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sl-feat\"\u003e\n\u003cdiv class=\"sl-feat-title\"\u003e600-989 cu ft range - large group capacity\u003c\/div\u003e\n\u003cp\u003eAt 600-989 cu ft, the Club K15G covers sauna rooms large enough to accommodate groups of bathers simultaneously - the room volumes typical of hotel sauna suites, sports centre sauna facilities, and large residential saunas for multi-family or group use. For rooms in this range, wall-mounted heaters are inadequate by both output and stone mass. The Club K15G provides the floor-standing, high-output, high-stone-mass configuration that large room group use demands.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sl-feat\"\u003e\n\u003cdiv class=\"sl-feat-title\"\u003eXenio CX45 or Fenix FX45 - full control capability\u003c\/div\u003e\n\u003cp\u003eThe CX45 and FX45 are Harvia's high-output controls compatible with heaters up to 18kW - the correct control tier for the 15kW Club K15G. The Fenix FX45 adds a 4.3\" touchscreen, MyHarvia 2 app connectivity, a smart timer that learns the heater's specific heat-up curve, and 3 programmable session presets. The CX45 provides the same high-output control in Harvia's standard Xenio wall-panel format. Both sold separately at BathingBrands.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sl-feat\"\u003e\n\u003cdiv class=\"sl-feat-title\"\u003eUL Listed - made in Finland\u003c\/div\u003e\n\u003cp\u003eAll Club Series heaters from Harvia are UL Listed for North American safety compliance. The Club K15G is designed and manufactured in Finland by Harvia, which has been producing sauna equipment for over 70 years. The deluxe stainless steel interior and exterior, combined with industrial-strength heating elements and the multi-layer outer shell, are built for years of safe and reliable operation in both residential and commercial sauna environments. We are an authorized Harvia dealer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr class=\"sl-divider\"\u003e\n\u003ch3\u003eAbout Harvia\u003c\/h3\u003e\n\u003cdiv class=\"sl-brand1\"\u003e\n\u003cimg alt=\"Harvia Club K15G 15kW floor-standing electric sauna heater stainless steel 600-989 cu ft commercial residential health club day spa\" src=\"https:\/\/prod-cms.bathingbrands.com\/sites\/default\/files\/2022-01\/harvia-club-k10-k12-k150-sauna-heater_1.jpg\" class=\"sl-brand-img\"\u003e\n\u003cdiv\u003e\n\u003cspan class=\"sl-brand-tag\"\u003eMade in Finland - UL Listed - Club Series\u003c\/span\u003e\n\u003ch4\u003eHarvia Club K15G. 15kW. 600-989 cu ft. Floor-standing. Multi-layer. Direct stone contact. Commercial grade.\u003c\/h4\u003e\n\u003cp\u003eHarvia is a Finnish sauna and spa company with over 70 years of manufacturing history. The Club K15G is Harvia's 15kW floor-standing commercial-grade electric sauna heater for rooms from 600 to 989 cubic feet - built for health clubs, day spas, hotels, sports centres, apartment buildings, and large residential saunas. Multi-layer construction, direct stone-to-element contact, deluxe stainless steel. Xenio CX45 or Fenix FX45 control required (sold separately). 132 lbs AC3000 stones required (3 boxes, sold separately). UL Listed. We are an authorized Harvia dealer.\u003c\/p\u003e\n\u003cul class=\"sl-check\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e15kW, 600-989 cu ft\u003c\/strong\u003e - 240V\/1PH, 70A, 4 AWG - UL Listed - made in Finland\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFloor-standing Club Series\u003c\/strong\u003e - continuous group use - commercial and residential\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-layer construction\u003c\/strong\u003e - cooler exterior - direct stone-to-element contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eXenio CX45 or Fenix FX45 required\u003c\/strong\u003e - sold separately\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e132 lbs AC3000 stones (3 boxes) required\u003c\/strong\u003e - sold separately\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sl-brand2\"\u003e\n\u003cdiv\u003e\n\u003cspan class=\"sl-brand-tag\"\u003eClub Series - K10G, K12G, K15G, and K18G\u003c\/span\u003e\n\u003ch4\u003eClub K15G vs Club Series lineup - choosing the right Club output\u003c\/h4\u003e\n\u003cp\u003eThe Harvia Club Series offers multiple output levels for large sauna rooms. The K15G (this listing) is the 15kW model for 600-989 cu ft. Other Club Series models are available at different output levels for rooms outside this range. All Club Series models share the same floor-standing format, stainless steel construction, multi-layer outer shell, direct stone-to-element contact, and Xenio CX45 \/ Fenix FX45 control compatibility. The correct Club Series model is determined by the adjusted cubic footage of the specific sauna room - use the Size Your Sauna resource and the Stone Requirement document below to confirm the K15G is appropriately sized before ordering. A licensed electrician is required for all Club Series installations. Do not connect to a GFI\/GFCI breaker.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cimg alt=\"Harvia Club Series K15G floor-standing commercial electric sauna heater lineup stainless steel floor model\" src=\"https:\/\/prod-cms.bathingbrands.com\/sites\/default\/files\/2022-01\/harvia-club-k10-k12-k150-sauna-heater_1.jpg\" class=\"sl-brand-img\"\u003e\n\u003c\/div\u003e\n\u003chr class=\"sl-divider\"\u003e\n\u003ch3\u003eManuals and Documents\u003c\/h3\u003e\n\u003cdiv class=\"sl-manual\"\u003e\n\u003cdiv class=\"sl-manual-item\"\u003e\n\u003ch6\u003eInstallation and Operation Manual\u003c\/h6\u003e\n\u003ca href=\"https:\/\/www.bathingbrands.com\/48501\/harvia\/club-k15g\/electric-heaters\" class=\"sl-doc-link\" target=\"_blank\"\u003e \u003csvg width=\"14\" height=\"14\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\"\u003e\u003cpath d=\"M14 2H6a2 2 0 0 0-2 2v16a2 2 0 0 0 2 2h12a2 2 0 0 0 2-2V8z\"\u003e\u003c\/path\u003e\u003cpolyline points=\"14 2 14 8 20 8\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e Installation and Operation Manual (PDF) \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sl-manual-item\"\u003e\n\u003ch6\u003eData Sheet\u003c\/h6\u003e\n\u003ca href=\"https:\/\/www.bathingbrands.com\/48501\/harvia\/club-k15g\/electric-heaters\" class=\"sl-doc-link\" target=\"_blank\"\u003e \u003csvg width=\"14\" height=\"14\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\"\u003e\u003cpath d=\"M14 2H6a2 2 0 0 0-2 2v16a2 2 0 0 0 2 2h12a2 2 0 0 0 2-2V8z\"\u003e\u003c\/path\u003e\u003cpolyline points=\"14 2 14 8 20 8\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e Data Sheet (PDF) \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sl-manual-item\"\u003e\n\u003ch6\u003eStone Requirement\u003c\/h6\u003e\n\u003ca href=\"https:\/\/www.bathingbrands.com\/48501\/harvia\/club-k15g\/electric-heaters\" class=\"sl-doc-link\" target=\"_blank\"\u003e \u003csvg width=\"14\" height=\"14\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\"\u003e\u003cpath d=\"M14 2H6a2 2 0 0 0-2 2v16a2 2 0 0 0 2 2h12a2 2 0 0 0 2-2V8z\"\u003e\u003c\/path\u003e\u003cpolyline points=\"14 2 14 8 20 8\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e Stone Requirement (PDF) \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sl-manual-item\"\u003e\n\u003ch6\u003eHarvia Suitable Sauna Stone Update 6\/22\u003c\/h6\u003e\n\u003ca href=\"https:\/\/www.bathingbrands.com\/48501\/harvia\/club-k15g\/electric-heaters\" class=\"sl-doc-link\" target=\"_blank\"\u003e \u003csvg width=\"14\" height=\"14\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\"\u003e\u003cpath d=\"M14 2H6a2 2 0 0 0-2 2v16a2 2 0 0 0 2 2h12a2 2 0 0 0 2-2V8z\"\u003e\u003c\/path\u003e\u003cpolyline points=\"14 2 14 8 20 8\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e Harvia Suitable Sauna Stone Update 6\/22 (PDF) \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"sl-manual-item\"\u003e\n\u003ch6\u003eHarvia Heater Elements\u003c\/h6\u003e\n\u003ca href=\"https:\/\/www.bathingbrands.com\/48501\/harvia\/club-k15g\/electric-heaters\" class=\"sl-doc-link\" target=\"_blank\"\u003e \u003csvg width=\"14\" height=\"14\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\"\u003e\u003cpath d=\"M14 2H6a2 2 0 0 0-2 2v16a2 2 0 0 0 2 2h12a2 2 0 0 0 2-2V8z\"\u003e\u003c\/path\u003e\u003cpolyline points=\"14 2 14 8 20 8\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003e Harvia Heater Elements (PDF) \u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cdiv class=\"sl-warranty\"\u003e\n\u003ch5\u003eHarvia limited warranty\u003c\/h5\u003e\n\u003cp\u003eThe Harvia Club K15G is covered by Harvia's limited warranty from the date of purchase. The warranty covers defects in manufacturing and materials under normal use conditions. The warranty does not cover damage caused by improper installation, use without the required stone load, use of incorrect stone type, connection to a GFI\/GFCI breaker, operating without the required Xenio CX45 or Fenix FX45 control, or failure to follow Harvia's installation and operating guidelines. A licensed electrician is required for all electrical connections. Proof of purchase from an authorized Harvia dealer is required for warranty claims. We are an authorized Harvia dealer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Harvia","offers":[{"title":"240V\/1PH (Home Use)","offer_id":52320404013338,"sku":"HRKGU15CU1UL","price":2999.0,"currency_code":"USD","in_stock":true},{"title":"208V\/3PH (Commercial Use)","offer_id":52320404046106,"sku":"HRKGU15CU3UL","price":2999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/1690\/0634\/files\/harvia-sauna-heater-harvia-club-k10g-10-kw-electric-sauna-heater-at-208v-3ph-1182036990.jpg?v=1780723519","url":"https:\/\/mediriser.com\/products\/harvia-club-k15g-club-series-15kw-sauna-heater","provider":"Mediriser","version":"1.0","type":"link"}